0D viewers DAQmxAI and DAQmxDualAI
These plugins acquire one (DAQmxAI) or two (DAQmxDualAI) analog inputs of a NI card, as a voltage between -10 V
and 10 V (differential terminals). They have been ported from the pydaqmx branch with the same names and settings,
and tested against a fake of the nidaqmx layer only, not yet on hardware.
They are also listed with the 1D viewers (DAQ_1DViewer_DAQmxAI, DAQ_1DViewer_DAQmxDualAI): the same plugins,
starting with the 1D display.
Configuration
Display type:
0Dgives the mean value of the samples,1Dgives the trace as a function of time.Frequency Acq.: the sampling frequency, in Hz.
Nsamples: the number of samples of one acquisition.
AI (
DAQmxAI) or AI0 and AI1 (DAQmxDualAI): the analog input channels, something likeDev[X]/ai[Y]. The two channels ofDAQmxDualAIare acquired together, with the same clock.
Use
The hardware averaging of PyMoDAQ is available: the acquisition is repeated and averaged. For other settings of the
inputs (range, termination, current or temperature), use the general NIDAQmx viewer.